MOBILE REPAIR WORKPLACE IN THE MOUNTED HALL FOR THE REPARATION OF THE AERIAL TECHNIQUE MOP
MOP is intended for the ensuring of the planned and unplanned maintenance and reparation of the damaged aerial technique, concretely transport and combat helicopters.
STRUCTURE OF THE WORKPLACE:
- mounted hall for the reparation of the aerial technique equipped by the set of air-conditioning, ventilation, heating, lighting and electric power distribution.
- The components are
- 2 entryways in sidewalls with the dimensions 2 × 2 m
- lamellar sandwich gates for the entrance of the helicopters with the dimensions 23,2 × 3,5 m
- gate for the entrance of the vehicle with the dimensions 3 × 3,5 m
- wind bracing
- set for the montage of the hall
- 10 containers positioned in the “U” pattern in the mounted hall with the following designation:
- 1 × control workplace
- 4 × workshop
- 4 × warehouse
- 1 × source container
OPERATING CONDITIONS:
operating temperatures – 20 °C to + 45 °C
BASIC TECHNICAL AND TACTICAL DATA:
inner width of the hall | 23,2 m |
inner lenght of the hall | 35,3 m |
inner height of the hall | 9,1 m |
side clearance | 5 m |
wind resistance | 40 m.s-1 |
snow resistance | 1 500 N/m2 |