MOBILE REPAIR WORKPLACE IN THE MOUNTED HALL FOR THE REPARATION OF THE AERIAL TECHNIQUE MOP

MOP is intended for the ensuring of the planned and unplanned maintenance and reparation of the damaged aerial technique, concretely transport and combat helicopters.

STRUCTURE OF THE WORKPLACE:

  • mounted hall for the reparation of the aerial technique equipped by the set of air-conditioning, ventilation, heating, lighting and electric power distribution.
  • The components are
    • 2 entryways in sidewalls with the dimensions 2 × 2 m
    • lamellar sandwich gates for the entrance of the helicopters with the dimensions 23,2 × 3,5 m
    • gate for the entrance of the vehicle with the dimensions 3 × 3,5 m
    • wind bracing
    • set for the montage of the hall
  • 10 containers positioned in the “U” pattern in the mounted hall with the following designation:
    • 1 × control workplace
    • 4 × workshop
    • 4 × warehouse
    • 1 × source container

OPERATING CONDITIONS:

operating temperatures – 20 °C to + 45 °C

BASIC TECHNICAL AND TACTICAL DATA:

inner width of the hall23,2 m
inner lenght of the hall35,3 m
inner height of the hall9,1 m
side clearance5 m
wind resistance40 m.s-1
snow resistance1 500 N/m2